Complications of circular plate fixation for four-corner arthrodesis.

Abstract Four corner arthrodesis is an accepted salvage operation for scapholunate advanced collapse and scaphoid non-union advanced collapse. Circular plates were introduced in 1999 and promoted as a rapid and more stable method for this procedure. A retrospective chart review was performed on all patients who were treated with the Spider Limited Wrist Fusion Plate (Kinetikos Medical Inc., San Diego, CA). Sixteen patients were identified and followed clinically and with X-rays for an average of 16 (range 5-38) months. Nine out of the 16 patients (56%) had complications, including non-union (25%), delayed union (6%), dorsal impingement (25%), radial styloid impingement (6%) and broken screws (13%).